2
Fault list – safety technology
Fault 13 Encoder 1
Manual – Fault Descriptions MOVISAFE
®
CS..A
10
Subfault: 13.60
Description: Travel limit exceeded
Response: FS – encoder fault
Cause
Measure
Travel limit violated for an application with limited
travel distance.
– Check the startup parameters.
– Check the application.
– Perform referencing again.
Subfault: 13.61
Description: Wrong number of bits per telegram
Response: FS – warning
Cause
Measure
The number of bits received per telegram does
not match the number of parameterized bits.
– Check the startup parameters.
– Check the wiring.
– Check interference sources.
Subfault: 13.62
Description: Wrong cycle frequency
Response: FS – warning
Cause
Measure
Measured clock does not correspond with param-
eterized clock.
– Check the startup parameters.
– Check the wiring.
– Check interference sources.
Subfault: 13.64
Description: Inconsistent or corrupt data
Response: FS – warning
Cause
Measure
Inconsistent or corrupt data detected during en-
coder evaluation.
– Check interference sources (e.g. from the area
of EMC).
– Check the encoder cable or shield.
– Check the startup parameters.
Subfault: 13.65
Description: Illumination color error
Response: FS – warning
Cause
Measure
The lighting color in the encoder data does not
match the lighting color in use.
– Switch the device off and on again.
– If the fault occurs repeatedly, replace the en-
coder and send it to SEW‑EURODRIVE together
with the fault number. For further support, contact
SEW‑EURODRIVE Service.
27799182/EN – 10/2022