2
Fault list – safety technology
Fault 32 Communication
Manual – Fault Descriptions MOVISAFE
®
CS..A
39
2.8
Fault 32 Communication
Subfault: 32.13
Description: Process data timeout
Fault class: Warning
Cause
Measure
Process data timeout.
– Switch the device off and on again.
– If the fault occurs repeatedly, replace the safety
card and send it together with the fault number to
SEW‑EURODRIVE. For further support, contact
SEW‑EURODRIVE Service.
Subfault: 32.14
Description: Internal communication error
Fault class: Warning
Cause
Measure
An error occurred in the non-safe communication. – Switch the device off and on again.
– If the fault occurs repeatedly, replace the safety
card and send it together with the fault number to
SEW‑EURODRIVE. For further support, contact
SEW‑EURODRIVE Service.
2.9
Fault 60 Safe digital input
Subfault: 60.19
Description: F-DI level change "cam slip adjustment" at wrong position
Response: FS – input fault
Cause
Measure
An F-DI edge was detected at an incorrect posi-
tion during slip adjustment. This can be due to the
following reasons:
– Cable breakage
– Line fault
– Incorrect parameter setting of the slip compen-
sation
– Check the cables.
– Check the parameter setting of the slip com-
pensation.
27799182/EN – 10/2022