Fault list – safety technology
Fault 25 Parameter memory monitoring
Manual – Fault Descriptions MOVISAFE
®
CS..A
36
2.6
Fault 25 Parameter memory monitoring
Subfault: 25.55
Description: Incompatible safety card parameter set on pluggable memory module
Fault class: Warning
Cause
Measure
Parameter set on pluggable memory module cre-
ated by incompatible safety card version.
Parameterize the safety card again and validate.
Subfault: 25.56
Description: Corrupt safety card parameter set on pluggable memory module
Fault class: Warning
Cause
Measure
Corrupt safety card parameter set on pluggable
memory module.
Parameterize the safety card again and validate.
Subfault: 25.57
Description: Internal communication error while accessing pluggable memory module
Fault class: Warning
Cause
Measure
Internal communication error while accessing
pluggable memory module.
– Switch the device off and on again.
– If the fault occurs repeatedly, replace the safety
card and send it together with the fault number to
SEW‑EURODRIVE. For further support, contact
SEW‑EURODRIVE Service.
Subfault: 25.58
Description: Error applying parameter set of safety card from pluggable memory module
Fault class: Warning
Cause
Measure
Failure to apply the parameter data set of the
safety card from the replaceable memory module
can have the following reasons:
– The "Assist CS.." tool is open.
– Another parameter setting process is running.
– Switch the device off and on again.
– If the fault occurs repeatedly, replace the safety
card and send it together with the fault number to
SEW‑EURODRIVE. For further support, contact
SEW‑EURODRIVE Service.
Subfault: 25.59
Description: Communication error with the basic unit
Response: FS – warning
Cause
Measure
An error prevented the changed configuration
from being saved to the replaceable memory
module.
Switch the device off and on again.
27799182/EN – 10/2022