2
Fault list – safety technology
Fault 66 Safety-related fault
Manual – Fault Descriptions MOVISAFE
®
CS..A
70
Subfault: 66.48
Description: Acknowledgment required after parameter set restore
Fault class: System error
Cause
Measure
Parameter set restored using non-safe communi-
cation.
Acknowledge the error.
Subfault: 66.49
Description: Acknowledgment required after delivery state
Fault class: System error
Cause
Measure
Safety card reset to delivery state.
Acknowledge the error.
Subfault: 66.50
Description: Incompatible data from safety key
Fault class: System error
Cause
Measure
Incompatible device version or device variant
written to safety key.
Transfer the data set to the safety card again us-
ing the "Assist CS.." tool.
Subfault: 66.51
Description: Wrong version of the basic unit for FSoE
Response: FS – warning
Cause
Measure
Only basic units from version 4 support using
FSoE.
Disable the function or update the basic unit.
Subfault: 66.52
Description: Wrong version of the basic unit for CIP Safety™
Response: FS – warning
Cause
Measure
Only basic units from version 7 support using CIP
Safety™.
Disable the function or update the basic unit.
Subfault: 66.53
Description: Wrong version of the basic unit for FSoE with SYSTEM profile
Response: FS – warning
Cause
Measure
Only basic units from version 4.1 support using
FSoE with SYSTEM profile.
Disable the function or update the basic unit.
27799182/EN – 10/2022