2
Fault list – safety technology
Fault 14 Encoder 2
Manual – Fault Descriptions MOVISAFE
®
CS..A
18
Subfault: 14.56
Description: Maximum speed exceeded while encoder fault muting is active
Response: FS – system error
Cause
Measure
Maximum permitted speed exceeded while en-
coder fault muting is active.
– Check the maximum speed of the application
while encoder fault muting is active and adjust if
necessary.
– Check the parameter setting of the safety card
and adjust if necessary.
Subfault: 14.57
Description: Maximum speed exceeded
Response: FS – encoder fault
Cause
Measure
Permitted maximum speed exceeded.
– Check the maximum speed of the application
and adjust if necessary.
– Check the parameter setting of the safety card
and adjust if necessary.
Subfault: 14.58
Description: Detection limit exceeded
Response: FS – warning
Cause
Measure
Speed exceeded sensing limit.
– Check the maximum speed of the application
and adjust if necessary.
– Check the parameter setting of the safety card
and adjust if necessary.
Subfault: 14.59
Description: Encoder no longer referenced
Response: FS – warning
Cause
Measure
Diagnostics error detected during encoder evalu-
ation. Referencing is canceled.
– Remove the cause of the error.
– Reference the encoder again.
Subfault: 14.60
Description: Travel limit exceeded
Response: FS – encoder fault
Cause
Measure
Travel limit violated for an application with limited
travel distance.
– Check the startup parameters.
– Check the application.
– Perform referencing again.
27799182/EN – 10/2022