2
Fault list – safety technology
Fault 67 Safe communication
Manual – Fault Descriptions MOVISAFE
®
CS..A
84
Subfault: 67.155
Description: Error in safety validator connection establishment engine TUNID
Response: FS – message
Cause
Measure
Error checking target unique network identifier
(TUNID).
– Make sure that the IP address in the originator
and the target is identical.
– Make sure that the SNN in the originator and in
the target is identical.
Subfault: 67.156
Description: Error in safety validator connection establishment engine SCID
Response: FS – message
Cause
Measure
Error checking safety configuration identifier
(SCID).
Check the configuration of the following SCID val-
ues:
– Combination of the values of the safety configu-
ration CRC (SCCRC) and the safety configuration
– Timestamp (SCTS)
Subfault: 67.157
Description: Error in safety validator connection establishment engine EKEY
Response: FS – message
Cause
Measure
Error in the electronic key.
Check the configuration of the target electronic
key in the engineering tool of the controller.
Subfault: 67.158
Description: Error in safety validator server client object timeout
Response: FS – message
Cause
Measure
Safety protocol signaled timeout.
– Make sure that the communication path was not
interrupted (cables, voltages, load).
– Make sure that the communication channel
between originator and target has been con-
figured correctly.
– Make sure that the monitoring times set in the
originator are not too low.
27799182/EN – 10/2022