2
Fault list – safety technology
Fault 66 Safety-related fault
Manual – Fault Descriptions MOVISAFE
®
CS..A
65
Subfault: 65.6
Description: SLA 2 limit acceleration exceeded in negative direction of movement
Fault class: Warning
Cause
Measure
SLA 2 limit acceleration exceeded in negative di-
rection of movement.
– Check the acceleration of the application while
the drive safety function is active, and adjust if
necessary.
– Check the parameter setting of the safety card
(limit acceleration SLA 2), and adjust if neces-
sary.
Subfault: 65.10
Description: SLA maximum speed exceeded in positive direction of movement
Response: FS – warning
Cause
Measure
General maximum speed exceeded in positive di-
rection of movement while SLA is active.
– Check the maximum speed of the application
while the drive safety function is active, and ad-
just if necessary.
– Check the parameter setting of the safety card
(maximum speed SLA 4), and adjust if necessary.
Subfault: 65.11
Description: SLA maximum speed exceeded in negative direction of movement
Response: FS – warning
Cause
Measure
General maximum speed exceeded in negative
direction of movement while SLA is active.
– Check the maximum speed of the application
while the drive safety function is active, and ad-
just if necessary.
– Check the parameter setting of the safety card
(maximum speed SLA 4), and adjust if necessary.
2.15
Fault 66 Safety-related fault
Subfault: 66.1
Description: Data storage problem during firmware update
Fault class: Warning
Cause
Measure
Data storage problem during firmware update.
If the fault occurs repeatedly, replace the safety
card and send it together with the fault number to
SEW‑EURODRIVE. For further support, contact
SEW‑EURODRIVE Service.
27799182/EN – 10/2022