S2600E/P CLI Reference Guide Chapter 3 IPv6 Configuration Commands
TENTATIVE
Indicate that the DAD is underway. The
address is a tentative before the DAD is
completed.
DUPLICATED Indicate
that
a
duplicate address exists.
DEPRECATED
Indicate that the preferred lifetime of the
address expires.
NODAD
Indicate that no DAD is implemented for
the address.
AUTOIFID
Indicate that the interface ID of the address
is automatically generated by the system,
which is usually an EUI-64 ID.
Ruijie#
show ipv6 interface vlan 1
ra-info
vlan 1: DOWN
RA timer is stopped
waits: 0, initcount: 3
statistics: RA(out/in/inconsistent): 4/0/0, RS(input): 0
Link-layer address: 00:00:00:00:00:01
Physical MTU: 1500
ND device advertisements live for 1800 seconds
ND device advertisements are sent every 200 seconds<240--160>
Flags: !M!O, Adv MTU: 1500
ND advertised reachable time is 0 milliseconds
ND advertised retransmit time is 0 milliseconds
ND advertised CurHopLimit is 64
Prefixes: (total: 1)
fec0:1:1:1::/64(Def,Auto,vltime: 2592000, pltime: 604800, flags:
LA)
Description of the fields in
ra-info
:
Field
Meaning
RA timer is stopped
(on)
Indicate whether the RA timer is started.
waits
Indicate that the RS is received but the
number of the responses is not available.
initcount
Indicate the number of the RAs when the
RA timer is restarted.
Summary of Contents for RG-S2600E Series
Page 1: ...CLI Reference Guide RG S2600E Series Switch RGOS 10 4 3 p1 1...
Page 5: ...Basic Configuration...
Page 83: ...Ethernet Switching...
Page 240: ...IPApplication...
Page 263: ...S2600E P CLI Reference Guide Chapter 1 IP Address Configuration Commands Platform description...
Page 317: ...S2600E P CLI Reference Guide Chapter 5 DHCP Relay Configuration Commands Platform description...
Page 335: ...Network Management and Monitoring...
Page 408: ...S2600E CLI Reference Guide Chapter 5 SPAN Configuration Commands...
Page 415: ...S2600E CLI Reference Guide Chapter 6 RSPAN Configuration Commands Platform description N A...
Page 416: ...Multicast Commands...
Page 449: ...S2600E P CLI Reference Guide Chapter 1 IGMP Snooping Commands Example3 Example4...
Page 450: ...S2600E P CLI Reference Guide Chapter 1 IGMP Snooping Commands...
Page 477: ...Security...
Page 878: ...ACL QOS...
Page 953: ...Reliability...
Page 1024: ...S2600E CLI Reference Guide Chapter 6 GRTD Configuration Commands Platform description...
Page 1031: ...S2600E CLI Reference Guide Chapter 6 GRTD Configuration Commands Platform description...
Page 1035: ...S2600E CLI Reference Guide Chapter 6 GRTD Configuration Commands 6 3 Display Related Commands...
Page 1121: ...System Management...