S2600E CLI Reference Guide Chapter 7 Syslog Configuration Commands
Command
Description
Related
commands
logging console
Set the severity of logs that are
allowed to be displayed on the
console.
7.1.6
logging file flash
Use this command to record logs in the flash. The
no
format of the command
disables the function.
logging file flash:filename
[
max-file-size
] [
level
]
no logging file
Parameter
Description
filename
Name of the log file of txt type
max-file-size
Maximal size of the log file in the range
128K to 6M bytes, 128K bytes by
default
Parameter
description
level
The severity of logs recorded in the log
files. The name of the severity or the
numeral can be used. By default, the
severity of logs recorded in the FLASH
is 6. For the details of log severity,
please see Table-1.
Default
configuration
Logs are not recorded in the FLASH.
Command
mode
Global configuration mode.
Usage
guidelines
If no
Syslog Server
is specified or it is not desired to
transfer logs in the network due to the consideration of
security purpose, it is possible to save the logs directly in
flash.
The extension of the log file is fixed as txt. Any
configuration of extension for the filename will be refused.
To record the logs into the expansion FLASH, The
expansion FLASH is required. If there is no expansion
FLASH, the logging file flash will be hidden automatically
and the related configuration will be denied.
Summary of Contents for RG-S2600E Series
Page 1: ...CLI Reference Guide RG S2600E Series Switch RGOS 10 4 3 p1 1...
Page 5: ...Basic Configuration...
Page 83: ...Ethernet Switching...
Page 240: ...IPApplication...
Page 263: ...S2600E P CLI Reference Guide Chapter 1 IP Address Configuration Commands Platform description...
Page 317: ...S2600E P CLI Reference Guide Chapter 5 DHCP Relay Configuration Commands Platform description...
Page 335: ...Network Management and Monitoring...
Page 408: ...S2600E CLI Reference Guide Chapter 5 SPAN Configuration Commands...
Page 415: ...S2600E CLI Reference Guide Chapter 6 RSPAN Configuration Commands Platform description N A...
Page 416: ...Multicast Commands...
Page 449: ...S2600E P CLI Reference Guide Chapter 1 IGMP Snooping Commands Example3 Example4...
Page 450: ...S2600E P CLI Reference Guide Chapter 1 IGMP Snooping Commands...
Page 477: ...Security...
Page 878: ...ACL QOS...
Page 953: ...Reliability...
Page 1024: ...S2600E CLI Reference Guide Chapter 6 GRTD Configuration Commands Platform description...
Page 1031: ...S2600E CLI Reference Guide Chapter 6 GRTD Configuration Commands Platform description...
Page 1035: ...S2600E CLI Reference Guide Chapter 6 GRTD Configuration Commands 6 3 Display Related Commands...
Page 1121: ...System Management...