User Manual 1178.4130.02 ─ 07
[SENSe:]SWEep:POINts
<SweepPoints>
This command defines the number of measurement points.
Parameters:
<SweepPoints>
<numeric value> (integer only)
Range:
101 to 2501
*RST:
201
Example:
//Define number of measurement points
SWE:POIN 1001
Manual operation:
See
19.16.6
Trace
Commands to configure traces described elsewhere.
●
Trace mode:
DISPlay<n>[:WINDow]:TRACe<t>:MODE
Note: Only "Clear/Write" and "Average" are supported by the VNA application.
●
Memory trace:
CALCulate<n>:MATH<t>:COPY:MEMory
DISPlay<n>[:WINDow]:TRACe<t>:MEMory[:STATe]
●
Data format of trace export:
TRACe[:DATA]?
This command queries the trace data (measurement results in graphical result dis-
plays).
Return values:
<Result>
The number of values depends on the number of measurement
points.
The unit depends on the measurement and the measurement
format.
Example:
//Query measurement results
TRAC?
Usage:
Query only
19.16.7
Marker
Commands to configure markers described elsewhere.
●
Marker state (on / off):
CALCulate<n>:MARKer<m>[:STATe]
CALCulate<n>:MARKer<m>:AOFF