Remote Control
R&S
®
FPC
227
User Manual 1178.4130.02 ─ 07
Prerequisites for this command
●
).
●
Turn off tracking generator (
●
).
Parameters:
<Frequency>
<numeric value>
Default unit: Hz
Example:
//Define fix frequency of generated signal
SOUR:TG ON
SOUR:TG:FREQ:AUTO OFF
SOUR:TG:FREQ 100MHZ
Manual operation:
See
SOURce:TG:FREQuency:AUTO
<State>
This command couples and decouples the output frequency of the signal source to the
center frequency.
Prerequisites for this command
●
).
●
Turn off tracking generator (
Parameters:
<State>
ON | 1
Generates a signal whose frequency corresponds to the center
frequency (signal source mode "Coupled CW").
You can define the center frequency with
OFF | 0
Generates a signal whose frequency remains the same (signal
source mode "CW").
You can define the fix output frequency with
Example:
//Couple signal source frequency to center frequency
SOUR:TG ON
SOUR:TG:FREQ:AUTO ON
//Define center and output frequency
FREQ:CENT 100MHZ
Manual operation:
See
SOURce:TG:POWer
<Level>
This command defines signal source output power.
Signal Source Configuartion