![Rohde & Schwarz FPC Series User Manual Download Page 320](http://html.mh-extra.com/html/rohde-and-schwarz/fpc-series/fpc-series_user-manual_1477824320.webp)
Remote Control
R&S
®
FPC
317
User Manual 1178.4130.02 ─ 07
Example:
//Query modulation error
CALC:MARK:FUNC:DDEM:MOER?
Usage:
Query only
CALCulate<n>:MARKer:FUNCtion:DDEMod:MPOWer[:RESult]?
This command queries the power of the carrier signal.
Suffix:
<n>
.
irrelevant
Return values:
<Power>
<numeric value>
Default unit: dBm
Example:
//Query carrier power
CALC:MARK:FUNC:DDEM:MPOW?
Usage:
Query only
[SENSe:]DDEMod
<Measurement>
This command selects the demodulation scheme of the signal you are measuring.
Parameters:
<Measurement>
ASK
Selects ASK modulation.
FSK
Selects FSK modulation.
*RST:
FSK
Example:
//Select measurement
DDEM ASK
Manual operation:
See
See
[SENSe:]DDEMod:FSK:OFFSet?
This command queries the measured frequency deviation of an FSK signal.
Prerequisites for this command
●
).
Return values:
<Frequency>
<numeric value>
Default unit: Hz
Example:
//Query frequency deviation
DDEM:FSK:OFFS?
Usage:
Query only
Remote Commands of the Digital Demodulation