![Rohde & Schwarz FPC Series User Manual Download Page 341](http://html.mh-extra.com/html/rohde-and-schwarz/fpc-series/fpc-series_user-manual_1477824341.webp)
Remote Control
R&S
®
FPC
338
User Manual 1178.4130.02 ─ 07
●
Marker position:
CALCulate<n>:MARKer<m>:X
CALCulate<n>:MARKer<m>:Y?
●
Marker position: set to peak:
CALCulate<n>:MARKer<m>:MAXimum[:PEAK]
●
Marker position: set to next peak:
CALCulate<n>:MARKer<m>:MAXimum:NEXT
●
Marker position: set to minimum:
CALCulate<n>:MARKer<m>:MINimum[:PEAK]
Commands to configure delta markers described elsewhere.
●
Delta marker state (on / off):
CALCulate<n>:DELTamarker<m>[:STATe]
CALCulate<n>:DELTamarker<m>:AOFF
●
Delta marker position:
●
CALCulate<n>:DELTamarker<m>:X:RELative
●
CALCulate<n>:DELTamarker<m>:Y?
●
Delta marker position: set to peak:
CALCulate<n>:DELTamarker<m>:MAXimum[:PEAK]
●
Delta marker position: set to next peak:
CALCulate<n>:DELTamarker<m>:MAXimum:NEXT
●
Delta marker position: set to minimum:
CALCulate<n>:DELTamarker<m>:MINimum[:PEAK]
.................................................................................338
.......................................................................................339
DISPlay<n>:IMPedance:REFerence:POSition
...................................................................340
CALCulate<n>:MARKer<m>:MODE
<MarkerMode>
This command selects the type of information a marker shows.
Suffix:
<n>
.
irrelevant
<m>
irrelevant
Parameters:
<MarkerMode>
See table below for supported parameters.
*RST:
NORMal
Manual operation:
See
ADMittance
admittance in complex format (real + imaginary)
IMPedance
impedance in complex format (real + imaginary)
Remote Commands of the VNA Application