Installation and Operation Manual 90DIB500IM02 – 5.2
71
DIB-500 R4.1
Installation
Connecting equipment racks (as of 5 carriers)
Connecting voltage supply cables to the top hat rail power supply unit
The voltage supply cables must be connected to the top hat rail power supply unit
before the power supply unit is installed.
Figure 4.10 shows the top hat rail power supply unit. The related table describes the
required terminals in detail.
Figure 4.10 Connectors for the voltage supply cable on the top hat rail power supply unit
The procedure for connecting voltage supply cables to the top hat rail power supply unit
is described in the following.
Proceed as follows to connect the voltage supply cable to the top hat rail power supply
unit:
Preparation:
✓
The network element must have been put out of operation temporarily, refer to sec-
tion 6.1 on page 133.
✓
The top cover of the equipment rack must have been removed.
✓
You need the tools and aids described in section 4.4.2.1 .
Table 4.5
Legend: Connectors for the voltage supply cable on the top hat rail power supply unit
No.:
Designation
Input/output
Wire colour
Connection between
1
- (DC)
Output: 24 V
DC
white
LRU and top hat rail power supply
unit
2
+ (1A)
brown
3
-
Input: 48 V
DC
white
top hat rail power supply unit and
voltage supply connector
4
+
brown
4
3
1 2