DIB-500 R4.1
Commissioning
Configuring the DIB-500 R4.1
114
Installation and Operation Manual 90DIB500IM02 – 5.2
17. Enter the corresponding IP address of the IntelPC, refer to Table 5.13 on page 108.
18. Enter the following command to change to the main menu:
Esc
19. Type in the following command:
:wq
20. Press the ENTER key to confirm your input.
➥
The changes will be saved and the configuration file closed.
21. Enter the following command to open the corresponding configuration file:
vi /etc/exports
➥
The "exports" configuration file is opened. The following output is an example:
# ================================================================
# ACCESSNET-T Configuration File
#
# Network : cta
# Description : cta
# Package Version : 7.0
# Network Element : bs01-002 (DIB1_12)
# Software Component : aeos-intel_1 (AEOS Intel)
# Software Version :
# Configuration Version : 1001281502
# Generated by : NMC-515 ConfigurationManager 03.01.00
# Date/Time : 28.01.2010 15:02:32 CET
# ================================================================
/ 10.101.101.49/
255.255.255.224(rw,no_root_squash,no_subtree_check)
/linuxppc 10.101.101.49/
255.255.255.224(rw,no_root_squash,no_subtree_check)
intelpc-1-1-1-1-bs01-002:~ #
Adaptation of the network mask not required
The network mask need not be adapted (here "255.255.255.224").
22. Navigate to the IP address of the entry "/" (here "10.101.101.49").
23. Enter the following command to delete the corresponding line:
x
24. Enter the following command to insert a corresponding figure:
i
25. Enter the corresponding IP address of the PowerPC, refer to Table 5.14 on
page Table 5.13.
26. Proceed analogously for the IP address of the "/linuxppc" entry.
27. Enter the following command to change to the main menu:
Esc (Escape)