Installation and Operation Manual 90DIB500IM02 – 5.2
69
DIB-500 R4.1
Installation
Connecting equipment racks (as of 5 carriers)
Connecting the voltage supply of the top hat rail power supply unit
The voltage supply of the top-hat rail power supply unit is connected directly via the cor-
responding terminals of the connection panel.
Figure 4.9 shows the corresponding terminals of the connection panel, to which the
wires of one of the voltage supply cables must be connected. The associated table
describes them in detail.
Figure 4.9 Terminals of the connection panel
The procedure for connecting the voltage supply cable for the top hat rail power supply
unit is described in the following.
Proceed as follows to connect the voltage supply cable of the top hat rail power supply
unit:
Preparation:
✓
You need the tools and aids described in section 4.4.2.1Tools and aids.
✓
The network element must have been put out of operation temporarily, refer to sec-
tion 6.1 on page 133.
✓
The top cover of the equipment rack must have been removed.
Table 4.3
Legend: Overview of the voltage supply of the LRU
No.:
Connection between
1
LRU and top hat rail power supply unit
2
top hat rail power supply unit and terminals of the connection panel
Table 4.4
Legend: Terminals of the connection panel
No.:
Wire colour
1
white
2
brown
2
1