Installation and Operation Manual 90DIB500IM02 – 5.2
33
DIB-500 R4.1
Product description
Components of the DIB-500 R4.1
3.2.3
Voltage supply and alarming system
The standard version of the DIB-500 R4.1 is operated at 48 V
DC
. Optionally, operation
with 100 V
AC
to 240 V
AC
is possible.
The standard version of the DIB-500 R4.1 with V
DC
voltage supply can optionally be
equipped with the following hardware components for the additional alarming system:
|
Mounting frame (optional for V
DC
voltage supply)
|
System controller (optional for V
DC
voltage supply)
|
Alarm input/output module (optional with V
DC
voltage supply)
The version with V
AC
voltage supply is already equipped with these constituents by
default and combined to form the V
AC
-voltage supply unit.
The constituents of the voltage supply and alarming system are described in the follow-
ing.
3.2.3.1
Mounting frame (optional for V
DC
voltage supply)
The mounting frame is not installed in the standard version of the DIB-500 R4.1 with
V
DC
voltage supply. The mounting frame is required if the optional system controller and
alarm input/output module hardware components for the alarming system have been
installed.
Figure 3.6 shows an example of the front view of a mounting frame without AC voltage
supply modules. The following table describes these in detail.
Figure 3.6 Front view of a mounting frame (without AC voltage supply modules)
11
RxD Ext
Interface (input) for connecting the reception paths of another
ACS for diversity reception (with
≥
4 carriers)
12
RxD (TIB B
2
)
Antenna B Rx output carrier TIB B
2
(only in the case of diversity)
13
Rx (TIB B
1
)
Antenna A Rx output carrier TIB B
1
14
Rx Ext
Antenna A interface (output) for connecting another ACS (with
≥
4 carriers)
15
Rx (TIB B
2
)
Antenna A Rx output carrier TIB B
2
16
CAN
CAN interface (optional)
17
AUX (TIB B)
Interface to the TIB B transceiver unit (including voltage supply)
1) depending on the ACS variant
Table 3.5
Legend: ACS front view
No.
Supply
Description
2
2
3
1