Installation and Operation Manual 90DIB500IM02 – 5.2
117
DIB-500 R4.1
Commissioning
Setting a cavity coupler to the TX frequency
Carry out the following steps:
1. Connect the one end of the network cable to the service connection, refer to Figure
Figure 5.27 Service connector
2. Connect the other end of the network cable to the Ethernet port of the service com-
puter.
3. Call the prompt via the Windows main menu ("Start“, "Run“).
4. Enter
the
cmd
command.
➥
The prompt window will be displayed:
Figure 5.28 Command prompt
5. Enter the command
telnet 10.xxx.xxx.XX 5100
to initiate a telnet session to
the BSC command shell to query the frequency of all active carriers.
xxx corresponds to the IP address of the BSC (PUC) depending on the site, refer to
the project-specific documents.
XX corresponds to the IP address of the PowerPC of the corresponding TIB.
6. Enter
u s3
at the command prompt to change to user level 3.