Installation and Operation Manual 90DIB500IM02 – 5.2
113
DIB-500 R4.1
Commissioning
Configuring the DIB-500 R4.1
8. Enter the following command to open the corresponding configuration file:
vi /etc/udhcpd.conf
➥
The "udhcpd.conf" configuration file is opened. The following output is an exam-
ple:
# ================================================================
# ACCESSNET-T Configuration File
#
# Network : cta
# Description : cta
# Package Version : 7.0
# Network Element : bs01-002 (DIB1_12)
# Software Component : aeos-intel_1 (AEOS Intel)
# Software Version :
# Configuration Version : 1001281502
# Generated by : NMC-515 ConfigurationManager 03.01.00
# Date/Time : 28.01.2010 15:02:32 CET
# ================================================================
start 10.101.101.49
end 10.101.101.49
interface eth1
siaddr 10.101.101.33
option lease 864000
option subnet 255.255.255.224
max_leases 1
dhcp_magkey 0x13242c8
opt bootfile autoscript.img
9. Navigate to the IP address of the "start" entry.
10. Enter the following command to delete the corresponding line:
x
11. Enter the following command to insert a corresponding figure:
i
12. Enter the corresponding IP address of the PowerPC, refer to Table 5.14 on
page 111.
The IP addresses in the "start" and "end" entries must be identical. Otherwise
the proper operation of the PowerPC is not ensured.
➔
Ensure that the IP addresses in the "start" and "end" entries are identical.
13. Proceed analogously for the IP address of the "end" entry.
14. Navigate to the IP address of the "siaddr" entry.
15. Enter the following command to delete the corresponding line:
x
16. Enter the following command to insert a corresponding figure:
i