Electrical
Requirements
B-5
Technical Specifications
Electrical Requirements
Environmental Requirements
Frequency
50/60 Hz (
±
3 Hz)
Power
Requirements
120V 50/60 Hz (about 110-130 VAC) or
220/240V 50 Hz (about 200-260 VAC)
Power
Consumption
120V (800 watts or less, 150w or less at standby with
fuser on)
220 to 240V (800 to 900w, 150w or less at standby with
fuser on)
Amperage
7.0 A or less (120
VAC)
4.0 A or less (220 to 240 VAC)
Noise Level
Idle—maximum 35 dB (A)
Printing—maximum 47 dB (A)
Ozone Density
The printer emits less than 0.1 parts per million (ppm) of
ozone maximum with a 100% duty cycle for 8 hours of
continuous operation
Relative
Humidity
Printing: 15-85% RH (non-condensing)
Storage (high): 85-95% RH (non-condensing)
Storage (low): 10-35% RH (non condensing)
Temperature
Range
Printing: 50-95° F (10-35° C)
Storage (high): 95-104° F (35-40° C)
Storage (low): -4-32° F (-20 to 0 ° C)
Atmospheric
Pressure
61.3-101.3 kPa (400-760 mm Hg)