3-45
3-7 Parameter List
3
Operation
Leve
l and ou
tp
ut termina
l
status
C055
Overtorque level
(Forward power
running)
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
100.
No
Yes
%
C056
Overtorque level
(Reverse
regeneration)
100.
No
Yes
%
C057
Overtorque level
(Reverse power
running)
100.
No
Yes
%
C058
Overtorque level
(Forward
regeneration)
100.
No
Yes
%
C061
Thermal warning
level
0. to 100.
80.
No
Yes
%
C062
Alarm code selection
00: Disabled
01: 3-bit
02: 4-bit
00
No
Yes
⎯
C063
0 Hz detection level
0.00 to 99.99
100.0
0.00
No
Yes
Hz
C064
Fin overheat warning
level
0. to 200.
120.
No
Yes
°
C
Parameter
No.
Function name
Monitor or data range
Default
setting
Changes during
operation
Unit