4-81
4-2 Function Mode
4
Func
tions
*1. When the emergency shutoff function is enabled (SW1 = ON), C001 and C003 are forced to change to "18"
(RS) and "64" (EMR), respectively. (You cannot intentionally set "64".)
If SW1 is turned on and then off, C003 is set to "no" (no allocation).
*: Parameters changeable during operation.
• The 1st/2nd/3rd control functions are displayed identically. You'll see which one is enabled by checking whether
the terminal is turned on/off.
• When both SET and SET3 terminals are turned on, priority is given to SET, and the 2nd control function is
enabled.
• During operation, you cannot switch between the 1st, 2nd, and 3rd control functions. You can switch them only
during stop.
The functions switchable via the SET/SET3 terminal are:
F002/F202/F302 *
: 1st/2nd/3rd
acceleration time
F003/F203/F303 *
: 1st/2nd/3rd
deceleration time
A003/A203/A303
: 1st/2nd/3rd
base frequency
A004/A204/A304
: 1st/2nd/3rd
maximum frequency
A020/A220/A320 *
: 1st/2nd/3rd
multi-step speed reference 0
A041/A241
: 1st/2nd
torque boost selection
A042/A242/A342 *
: 1st/2nd/3rd
manual torque boost voltage
A043/A243/A343 *
: 1st/2nd/3rd
manual torque boost frequency
A044/A244/A344
: 1st/2nd/3rd
V/f characteristics selection
A046/A246 *
: 1st/2nd
automatic torque boost
voltage compensation gain
A047/A247 *
: 1st/2nd
automatic torque boost slip
compensation gain
A061/A261 *
: 1st/2nd
frequency upper limit
A062/A262 *
: 1st/2nd
frequency lower limit
A092/A292/A392 *
: 1st/2nd/3rd
acceleration time 2
A093/A293/A393 *
: 1st/2nd/3rd
deceleration time 2
A094/A294
: 1st/2nd
2-step acceleration/deceleration
selection
A095/A295
: 1st/2nd
2-step acceleration frequency
A096/A296
: 1st/2nd
2-step deceleration frequency
b012/b212/b312 *
: 1st/2nd/3rd
electronic thermal level
b013/b213/b313 *
: 1st/2nd/3rd
electronic thermal characteristics
selection
H002/H202
: 1st/2nd
motor parameter selection
H003/H203
: 1st/2nd
motor capacity selection
H004/H204
: 1st/2nd
motor pole number selection
H005/H205 *
: 1st/2nd
speed response
H006/H206/H306 *
: 1st/2nd/3rd
stabilization parameter
H020/H220
: 1st/2nd
motor parameter R1
H021/H221
: 1st/2nd
motor parameter R2
H022/H222
: 1st/2nd
motor parameter L
H023/H223
: 1st/2nd
motor parameter I0
H024/H224
: 1st/2nd
motor parameter J
H030/H230
: 1st/2nd
motor parameter R1 (auto-tuning)
H031/H231
: 1st/2nd
motor parameter R2 (auto-tuning)
H032/H232
: 1st/2nd
motor parameter L (auto-tuning)
H033/H233
: 1st/2nd
motor parameter I0 (auto-tuning)
H034/H234
: 1st/2nd
motor parameter J (auto-tuning)
H050/H250 *
: 1st/2nd
PI proportional gain
H051/H251 *
: 1st/2nd
PI integral gain
H052/H252 *
: 1st/2nd
P proportional gain
H060/H260 *
: 1st/2nd
Limit at 0 Hz
In
v
er
ter
U/T1
V/T2
W/T3
SET
SET3
CM1
Motor 1
Motor 2
Motor 3
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......