4-79
4-2 Function Mode
4
Func
tions
• You can select NO- or NC-contact input for each multi-function input terminal.
C001 to
C008
55
FOC : Preliminary excitation
Preliminary excitation function
56
Not used
⎯
57
Not used
58
Not used
59
Not used
60
Not used
61
Not used
62
Not used
63
Not used
65
AHD : Analog command held
Analog command held
66
CP1 : Position command selection 1
Absolute position control mode
67
CP2 : Position command selection 2
68
CP3 : Position command selection 3
69
ORL : Zero return limit signal
⎯
70
ORG : Zero return startup signal
71
FOT : Forward driving stop
72
ROT : Reverse driving stop
73
SPD : Speed/Position switching
74
PCNT : Pulse counter
Multi-function pulse counter
75
PCC : Pulse counter clear
no
NO
: No allocation
⎯
⎯
Parameter
No.
Data
Function name
Reference item
Page
Parameter
No.
Function name
Data
Default
setting
Unit
C011 to
C018
Multi-function input
operation selection
00: NO contact
01: NC contact
• You can set NO- and NC-contact inputs
individually for multi-function input terminals S1 to
S8 and the FW terminal.
• NO contact: "ON" with the contact closed, "OFF"
with the contact open.
• NC contact: "ON" with the contact open. "OFF"
with the contact closed.
• A terminal with reset (RS) setting functions as NO
contact only.
00
⎯
C019
FW terminal operation
selection
00
⎯
Related functions
C001 to C008
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......