![background image](http://html.mh-extra.com/html/omron/3g3rx-series/3g3rx-series_user-manual_742806211.webp)
4-102
4-2 Function Mode
4
Functions
Starting Contact Signal
• While the Inverter is receiving the RUN command, a starting contact signal is output.
• The output is enabled regardless of the setting of RUN command source selection A002.
• If inputs FW and RV are simultaneously turned on, the Inverter stops.
Fin Overheat Warning
• This function monitors the Inverter's internal fin temperature and outputs a signal when the
temperature exceeds the fin overheat warning level (C064).
Parameter No.
Function name
Data
Default setting
Unit
C021 to C025
Multi-function output
terminal selection
41: FR (starting contact signal)
⎯
⎯
C026
Relay output (MA, MB)
function selection
05
Forward command
Reverse command
Starting contact signal (FR)
Parameter No.
Function name
Data
Default setting
Unit
C021 to C025
Multi-function output
terminal selection
42: OHF (cooling fin overheat warning)
⎯
⎯
C026
Relay output (MA, MB)
function selection
05
C064
Fin overheat warning
level
0. to 200.: Set a temperature to output the
overheat warning signal.
120
°
C
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......