4-175
4-4 Communication Function
4
Func
tions
0030h
Fault monitor 4 factor
d084
R
See "Inverter Trip Factor List"
(page 4-176).
⎯
0031h
Fault monitor 4 Inverter status
See "Inverter Trip Factor List"
(page 4-176).
⎯
0032h
Fault monitor 4 frequency (HIGH)
0 to 40000
0.01
[Hz]
0033h
Fault monitor 4 frequency (LOW)
0034h
Fault monitor 4 current
Output current value at the time of
tripping
0.1 [A]
0035h
Fault monitor 4 voltage
DC input voltage at the time of tripping
1 [V]
0036h
Fault monitor 4 RUN time (HIGH)
Total RUN time before the trip
1 [h]
0037h
Fault monitor 4 RUN time (LOW)
0038h
Fault monitor 4 ON time (HIGH)
Total power ON time before the trip
1 [h]
0039h
Fault monitor 4 ON time (LOW)
003Ah
Fault monitor 5 factor
d085
R
See "Inverter Trip Factor List"
(page 4-176).
⎯
003Bh
Fault monitor 5 Inverter status
See "Inverter Trip Factor List"
(page 4-176).
⎯
003Ch
Fault monitor 5 frequency (HIGH)
0 to 40000
0.01
[Hz]
003Dh
Fault monitor 5 frequency (LOW)
003Eh
Fault monitor 5 current
Output current value at the time of
tripping
0.1 [A]
003Fh
Fault monitor 5 voltage
DC input voltage at the time of tripping
1 [V]
0040h
Fault monitor 5 RUN time (HIGH)
Total RUN time before the trip
1 [h]
0041h
Fault monitor 5 RUN time (LOW)
0042h
Fault monitor 5 ON time (HIGH)
Total power ON time before the trip
1 [h]
0043h
Fault monitor 5 ON time (LOW)
0044h
Fault monitor 6 factor
d086
R
See "Inverter Trip Factor List"
(page 4-176).
⎯
0045h
Fault monitor 6 Inverter status
See "Inverter Trip Factor List"
(page 4-176).
⎯
0046h
Fault monitor 6 frequency (HIGH)
0 to 40000
0.01
[Hz]
0047h
Fault monitor 6 frequency (LOW)
0048h
Fault monitor 6 current
Output current value at the time of
tripping
0.1 [A]
0049h
Fault monitor 6 voltage
DC input voltage at the time of tripping
1 [V]
004Ah
Fault monitor 6 RUN time (HIGH)
Total RUN time before the trip
1 [h]
004Bh
Fault monitor 6 RUN time (LOW)
004Ch
Fault monitor 6 ON time (HIGH)
Total power ON time before the trip
1 [h]
004Dh
Fault monitor 6 ON time (LOW)
Register
No.
Function name
Function
code
R/W
Monitor and setting parameters
Resolution
Note 1: The Inverter's rated current is "1000".
Note 2: If the set value is "10000" (100.0 sec) or more, the value in the second decimal place is ignored.
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......