![background image](http://html.mh-extra.com/html/omron/3g3rx-series/3g3rx-series_user-manual_742806370.webp)
7-21
7-3 Options
7
Speci
fications
3G3AX-RBC12001
Specifications
150
170
7
110
10
390
410
Compact type
(3G3AX-RBA
)
Standard type
(3G3AX-RBB
)
Medium capacity type
(3G3AX-RBC
)
Model
1201
1202
1203
1204
2001
2002
3001
4001
4001
6001
12001
Resistance
Capacity
120 W
200 W
300 W
400 W
400 W
600 W
1200 W
Resistance
(
Ω
)
180
100
50
35
180
100
50
35
50
35
17
Allowable
braking
frequency (%)
5
2.5
1.5
1.0
10
7.5
7.5
7.5
10
Allowable
continuous
braking time (s)
20
12
5
3
30
20
10
Weight (kg)
0.27
0.97
1.68
2.85
2.5
3.6
6.5
Fault detection
function
Built-in thermal (Contact capacity: 240 V AC 2 A max.
Minimum current: 5 mA,
Normally ON (NC contact)
Built-in temperature fuse (recovery impossible)
Built-in temperature relay,
Normally ON (NC contact)
Contact capacity:
240 V AC 3 A (R load),
0.2 A (L load), 36 V DC 2 A
(R load)
Genera
l sp
ecification
s
Ambient
temperature
-10
°
C to 50
°
C
Humidity
20% to 90% (RH) with no condensation
Vibration
5.9 m/s (0.6 G) 10 to 55 Hz Complies with JISC0911
Location
At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Cooling
method
Self-cooling
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......