4-196
4-4 Communication Function
4
Functions
1415h
Multi-function output
terminal P1 selection
C021
R/W
0: RUN (signal during RUN)
1: FA1 (constant speed arrival signal)
2: FA2 (over set frequency arrival signal)
3: OL (overload warning)
4: OD (excessive PID deviation)
5: AL (alarm output)
6: FA3 (set-frequency-only arrival signal)
7: OTQ (overtorque)
8: IP (signal during momentary power interruption)
9: UV (signal during undervoltage)
10: TRQ (signal during torque limit)
11: RNT (RUN time exceeded)
12: ONT (ON time exceeded)
13: THM (thermal warning)
19: BRK (brake release)
20: BER (brake error)
21: ZS (0 Hz signal)
22: DSE (excessive speed deviation)
23: POK (position ready)
24: FA4 (set frequency exceeded 2)
25: FA5 (set frequency only 2)
26: OL2 (overload warning 2)
27: FVDc (analog FV disconnection detection)
28: FIDc (analog FI disconnection detection)
29: FEDc (analog FE disconnection detection)
31: FBV (PID FB status output)
32: NDc (network error)
33: LOG1 (logic operation output 1)
34: LOG2 (logic operation output 2)
35: LOG3 (logic operation output 3)
36: LOG4 (logic operation output 4)
37: LOG5 (logic operation output 5)
38: LOG6 (logic operation output 6)
39: WAC (capacitor life warning signal)
40: WAF (fan life warning signal)
41: FR (RUN command signal)
42: OHF (fin overheat warning)
43: LOC (light load detection signal)
44: Not used
45: Not used
46: Not used
47: Not used
48: Not used
49: Not used
50: IRDY (operation ready signal)
51: FWR (forward run signal)
52: RVR (reverse run signal)
53: MJA (fatal fault signal)
54: WCFV (window comparator FV)
55: WCFI (window comparator FI)
56: WCFE (window comparator FE)
(When alarm code output is selected in C062,
AC0 to AC2, or AC0 to AC3 (ACn: alarm code
output) are forced to be allocated to multi-
function output terminals P1 to P3, or P1 to
P4.)
⎯
1416h
Multi-function output
terminal P2 selection
C022
R/W
⎯
1417h
Multi-function output
terminal P3 selection
C023
R/W
⎯
1418h
Multi-function output
terminal P4 selection
C024
R/W
⎯
1419h
Multi-function output
terminal P5 selection
C025
R/W
⎯
141Ah
Relay output (MA, MB)
function selection
C026
R/W
⎯
Register
No.
Function name
Function
code
R/W
Monitor and setting parameters
Resolution
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......