Note 3: Acceleration/deceleration time varies depending on fluctuations in current value, even with
the same motor.
Note 4: The automatic optimum acceleration/deceleration setting is enabled only during V/f control.
When sensorless vector control is selected, the Inverter performs normal operation.
Note 5: If the jogging operation is performed when the automatic operation is selected, the Inverter
performs automatic acceleration, which is different from normal jogging operation.
Note 6: When the applied load is larger than the rating, deceleration time may be prolonged.
Note 7: If acceleration and deceleration are frequently repeated, the Inverter may trip.
Note 8: When the internal braking circuit is used, or when the regenerative braking unit is externally
installed, the motor cannot stop within the specified deceleration time because of braking
resistance. In this case, do not use the automatic optimum acceleration/deceleration
function.
Note 9: When using a lower rank motor size than specified for the Inverter, enable the overload limit
function (b021), and set the overload limit level (b022) to 1.5 times the rated current of the
motor.
2-step Acceleration/Deceleration Function
• By setting this function, you can change the acceleration/deceleration time during acceleration/
deceleration.
* To switch to the 2nd/3rd control, allocate 08 (SET)/17 (SET3) to the desired multi-function input and then turn it
on.
Parameter No.
Function name
Data
Default setting
Unit
A092
Acceleration time 2
0.01 to 99.99
100.0 to 999.9
1000. to 3600.
15.0
s
A292
*2nd acceleration time 2
s
A392
*3rd acceleration time 2
s
A093
Deceleration time 2
0.01 to 99.99
100.0 to 999.9
1000. to 3600.
15.0
s
A293
*2nd deceleration time 2
s
A393
*3rd deceleration time 2
s
A094
2-step acceleration/
deceleration selection
00: Switched via multi-function input 09
(2CH) (example 1)
01: Switched by setting (example 2)
02: Enabled only when switching forward/
reverse (example 3)
00
⎯
A294
*2nd 2-step acceleration/
deceleration selection
A095
2-step acceleration
frequency
0.00 to 99.99
100.0 to 400.0
0.0
Hz
A295
*2nd 2-step acceleration
frequency
A096
2-step deceleration
frequency
0.00 to 99.99
100.0 to 400.0
00
Hz
A296
*2nd 2-step deceleration
frequency
Related functions
F002, F202, F302, F003, F203, F303, C001 to C008
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......