App-10
Appendix-1 Parameter List
Appe
ndix
RU
N mod
e
, Accele
ration/Dece
leratio
n
fun
c
ti
ons
A085
RUN mode selection
00: Normal operation
01: Energy-saving operation
02: Automatic operation
00
No
No
⎯
A086
Energy-saving
response/accuracy
adjustment
0.0 to 100.0
50.0
Yes
Yes
⎯
A092
Acceleration time 2
0.01 to 99.99
100.0 to 999.9
1000. to 3600.
15.00
Yes
Yes
s
A292
* 2nd acceleration
time 2
15.00
A392
* 3rd acceleration
time 2
15.00
A093
Deceleration time 2
15.00
A293
* 2nd deceleration
time 2
15.00
A393
* 3rd deceleration
time 2
15.00
A094
2-step acceleration/
deceleration
selection
00: Switched via multi-function input 09
(2CH)
01: Switched by setting
02: Enabled only when switching forward/
reverse
00
No
No
⎯
A294
* 2nd 2-step
acceleration/
deceleration
selection
00
A095
2-step acceleration
frequency
0.00 to 99.99
100.0 to 400.0
0.00
No
No
Hz
A295
* 2nd 2-step
acceleration
frequency
0.00
A096
2-step deceleration
frequency
0.00
No
No
Hz
A296
* 2nd 2-step
deceleration
frequency
0.00
A097
Acceleration pattern
selection
00: Line
01: S-shape curve
02: U-shape curve
03: Inverted U-shape curve
04: EL-S-shape curve
00
No
No
⎯
A098
Deceleration pattern
selection
00
No
No
⎯
Parameter
No.
Function name
Monitor or data range
Default
setting
Changes during
operation
Unit
Page
Normal b031 = 10
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...