4-59
4-2 Function Mode
4
Func
tions
Reverse Rotation Prevention Function
• This function is enabled when "03" (sensorless vector control), "04" (0-Hz sensorless vector
control), or "05" (sensor vector control) is selected in control method A044/A244.
• Because of the Inverter's control characteristics, the Inverter may output a rotation signal in the
direction opposite to that of the RUN command (e.g. in a low-speed range). If the motor's reverse
rotation may cause a problem (e.g. damage to the machine driven by the motor), set reverse
rotation prevention selection b046 to "enabled".
Torque LADSTOP Function
• If "03" (sensorless vector control), "04" (0-Hz sensorless vector control), or "05" (sensor vector
control) is selected in control method A004/A244, this function temporarily stops the frequency
deceleration function (LAD) when the torque limit function is activated.
Parameter No.
Function name
Data
Default setting
Unit
A044/A244
V/f characteristics
selection
03: Sensorless vector
04: 0-Hz sensorless vector
05: Sensor vector (A244 is blank.)
00
⎯
b046
Reverse rotation
prevention selection
00: Disabled
01: Enabled
00
⎯
Parameter No.
Function name
Data
Default setting
Unit
A044/A244
V/f characteristics
selection
03: Sensorless vector
04: 0-Hz sensorless vector
05: Sensor vector (A344 is blank.)
00
⎯
b040
Torque limit selection
00: Four-quadrant separate setting
01: Terminal switch
02: Analog input
03: Option 1
04: Option 2
00
⎯
b041
Torque limit 1
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
Forward power running
under four-quadrant separate setting
150.
%
b042
Torque limit 2
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
Reverse regeneration
under four-quadrant separate setting
b043
Torque limit 3
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
Reverse power running
under four-quadrant separate setting
b044
Torque limit 4
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
Forward regeneration
under four-quadrant separate setting
b045
Torque LADSTOP
selection
00: Disabled
01: Enabled
00
⎯
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......