App-36
Appendix-1 Parameter List
Appe
ndix
Options
P001
Operation selection
at option 1 error
00: Trip
01: Continues operation
00
No
Yes
⎯
P002
Operation selection
at option 2 error
00: Trip
01: Continues operation
00
No
Yes
⎯
P011
Encoder pulses
128. to 9999.
1000 to 6553 (10000 to 65535)
1024.
No
No
Pulse
P012
V2 control mode
selection
00: ASR (speed control mode)
01: APR (pulse train position control mode)
02: APR2 (absolute position control mode)
03: HAPR (High resolution absolute position
control mode)
00
No
No
⎯
P013
Pulse train mode
selection
00: Mode 0
01: Mode 1
02: Mode 2
00
No
No
⎯
P014
Orientation stop
position
0. to 4095.
0.
No
Yes
⎯
P015
Orientation speed
setting
Starting frequency to Max. frequency (upper
limit: 120.0)
5.00
No
Yes
Hz
P016
Orientation direction
setting
00: Forward side
01: Reverse side
00
No
No
⎯
Parameter
No.
Function name
Monitor or data range
Default
setting
Changes during
operation
Unit
Page
Normal b031 = 10
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......