4-67
4-2 Function Mode
4
Func
tions
Initialization Method
After setting the above parameter, use the following method to initialize.
Note: You cannot initialize analog input adjustments C081, C082, C083, C121, C122, and C123, as well as
thermistor adjustment C085.
(1) Press the STOP/RESET key with the Mode and
Decrement keys pressed simultaneously.
• Release the STOP/RESET key when the display
blinks.
(The display changes as shown below.)
• Release the Mode and Decrement keys.
(2) Initializing
(3) Initialization completes when "d001" appears on the
monitor.
Check that the data is initialized.
8k8k8k8