3-34
3-7 Parameter List
3
Operation
Torque
li
mi
t
b040
Torque limit selection
00: Four-quadrant separate setting
01: Terminal switch
02: Analog input
03: Option 1
04: Option 2
00
No
Yes
-
⎯
b041
Torque limit 1
(Four-quadrant mode
forward power
running)
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
no (Torque limit disabled)
150.
No
Yes
%
b042
Torque limit 2
(Four-quadrant mode
reverse
regeneration)
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
no (Torque limit disabled)
150.
No
Yes
%
b043
Torque limit 3
(Four-quadrant mode
reverse power
running)
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
no (Torque limit disabled)
150.
No
Yes
%
b044
Torque limit 4
(Four-quadrant mode
forward
regeneration)
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
no (Torque limit disabled)
150.
No
Yes
%
b045
Torque LADSTOP
selection
00: Disabled
01: Enabled
00
No
Yes
⎯
Parameter
No.
Function name
Monitor or data range
Default
setting
Changes during
operation
Unit
Page
Normal b031 = 10
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......