4-57
4-2 Function Mode
4
Func
tions
User Parameter Automatic Setting Function
• When user parameter automatic setting function b039 is set to "01" (enabled), the parameters
subjected to a data change are automatically stored in sequence (from U001 to U012). This data
can be used as changed data.
• The screen information is stored when the Enter key is pressed. The monitor screens (d***) are
also stored in the same manner.
• U001 is the most recent parameter, and U012 is the oldest.
• The same parameter cannot be stored. If the number of parameters stored exceeds 12, the oldest
data (U012) is erased.
Torque Limit Function
• This function limits motor output torque when "03" (sensorless vector control), "04" (0-Hz
sensorless vector control), or "05" (sensor vector control) is selected in control method A044/A244.
Parameter No.
Function name
Data
Default setting
Unit
b039
User parameter automatic
setting function selection
00: Disabled
01: Enabled
00
⎯
Related functions
U001 to U012
Parameter No.
Function name
Data
Default setting
Unit
A044/A244
V/f characteristics
selection
03: Sensorless vector
04: 0-Hz sensorless vector
05: Sensor vector (A244 is blank.)
00
⎯
b040
Torque limit selection
00: Four-quadrant separate setting
01: Terminal switch
02: Analog input
03: Option 1
04: Option 2
00
⎯
b041
Torque limit 1
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
Forward power running
under four-quadrant separate setting
150.
%
b042
Torque limit 2
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
Reverse regeneration
under four-quadrant separate setting
150.
%
b043
Torque limit 3
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
Reverse power running
under four-quadrant separate setting
150.
%
b044
Torque limit 4
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
Forward regeneration
under four-quadrant separate setting
150.
%
C001 to C008
Multi-function inputs
1 to 8 selection
40: Torque limit enabled
41: Torque limit switching 1
42: Torque limit switching 2
⎯
⎯
C021 to C025
Multi-function output
terminal selection
10: During torque limit
⎯
⎯
Related functions
A044, A244, C001 to C008
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......