![background image](http://html.mh-extra.com/html/omron/3g3rx-series/3g3rx-series_user-manual_742806205.webp)
4-96
4-2 Function Mode
4
Functions
Constant Speed Arrival Output (01: FA1)
A signal is output when the output frequency has reached the level set in the frequency setting
(F001, A020, A220, and A320) or multi-step speed (A021 to A035).
Set-frequency-exceeded Output (02: FA2, 24: FA4)
A signal is output when the output frequency has exceeded the arrival frequencies during
acceleration/deceleration set in [C042, C043 (FA2)] and [C045, C046 (FA4)].
Set-frequency-only Output (06: FA3, 25: FA5)
A signal is output when the output frequency equals the arrival frequencies during acceleration/
deceleration set in [C042, C043 (FA3)] and [C045, C046 (FA5)].
Output frequency
f
on
f
off
FA1
Set frequency
f
on
: 1% of the max. frequency
f
off
: 2% of the max. frequency
(Example) Max. frequency f
max
= 120 (Hz)
Set frequency f
set
= 60 (Hz)
f
on
= 120 × 0.01 = 1.2 (Hz)
f
off
= 120 × 0.02 = 2.4 (Hz)
During acceleration: ON at 60 - 1.2 = 58.8 (Hz)
During deceleration: OFF at 60 - 2.4 = 57.6 (Hz)
Output frequency
f
on
f
off
FA2/FA4
f
on
: 1% of the max. frequency
f
off
: 2% of the max. frequency
C042/C045
C043/C046
Output frequency
f
on
f
off
FA3/FA5
f
on
: 1% of the max. frequency
f
off
: 2% of the max. frequency
C042/C045
C043/C046
f
on
f
off
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......