4-38
4-2 Function Mode
4
Functions
• Select an acceleration/deceleration time switching method from the following three:
Switching via a multi-function input
Automatic switching at a specified frequency
Automatic switching only when switching between forward/reverse
If the 3rd control function is selected, however, switching by the 2-step acceleration/deceleration
frequency is disabled.
• To switch via a multi-function input, allocate 09 (2CH) to any of C001 to C008.
Acceleration/Deceleration Pattern
• Acceleration/deceleration pattern can be set for each system.
(Example 1) When A094/A294 is set to 00
(Example 2) When A094/A294 is set to 01
(Example 3) When A094/A294 is set to 02
FW
2CH
Output
frequency
Acceleration
time 1
Deceleration
time 2
Deceleration
time 1
F002/F202/
F302
A092/
A292/
A392
A093/A293/
A393
F003/F203/
F303
Acceleration
time 2
FW
Output
frequency
Acceleration 1
Acceleration 2
Deceleration 2
Deceleration 1
F002/F202 A092/
A292
A093/
A293
F003/F203
A095/A295
A096/A296
Acceleration
time 1
Deceleration
time 1
Acceleration
time 2
Deceleration
time 2
FW
2CH
Output
frequency
Acceleration
time 1
Acceleration
time 2
Deceleration
time 2
Deceleration
time 1
F002/F202/
F302
A092/A292/
A392
A093/A293/
A393
F003/F203/
F303
Parameter No.
Function name
Data
Default setting
Unit
A097
Acceleration pattern selection
00: Line
01: S-shape curve
02: U-shape curve
03: Inverted U-shape curve
04: EL-S-shape curve
00
⎯
A098
Deceleration pattern selection
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......