4-97
4-2 Function Mode
4
Func
tions
Overtorque (OTQ)
• This function outputs a signal when detecting a motor output torque estimated value exceeding a
specified level.
• Enabled when "overtorque signal" is selected in the multi-function output selection. You can use
this function only when "sensorless vector control", "0-Hz sensorless vector control", or "sensor
vector control" is selected in V/f characteristics selection A044/A244. With other settings, the
output is unstable.
• For elevating machines, use this signal for releasing the brake. To close the brake, use the
frequency arrival signal.
Parameter No.
Function name
Data
Default setting
Unit
C021 to C025
Multi-function output
terminal selection
07: OTQ: Overtorque signal
-
⎯
C026
Relay output (MA, MB)
function selection
05
C055
Overtorque level
(Forward power running)
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
OTQ signal output level for forward
power running
100.
%
C056
Overtorque level
(Reverse regeneration)
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
OTQ signal output level for reverse
regeneration
100.
%
C057
Overtorque level
(Reverse power running)
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
OTQ signal output level for reverse
power running
100.
%
C058
Overtorque level
(Forward regeneration)
0. to 200. (0.4 to 55 kW)
0. to 180. (75 to 132 kW)
OTQ signal output level for forward
regeneration
100.
%
Related functions
A044, A244, A344, C063
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......