Chapter 4
4-4
SYSDRIVE Inverter Settings
■
Switching of Frequency References from DeviceNet Communications
There is a switching signal, “Net. Ref.,” for frequency references (speed references) from the stan-
dard remote I/O of the DeviceNet Communications Unit. The input method for frequency references
can be changed in the following ways using the “Net. Ref.” signal.
Net. Ref. = 1 (ON)
Enables frequency references from DeviceNet communications (remote I/O frequency references
become valid) regardless of the setting in n004.
Net. Ref. = 0 (OFF)
Enables the frequency reference setting in n004.