Chapter 1
1-11
Functions and System Configuration
1-4
DeviceNet Features
■
System Configuration Example
■
Multi-vendor Network
The DeviceNet conforms to the DeviceNet open field network specification, which means that
devices (Masters and Slaves) produced by other manufacturers can also be connected to the Net-
work. Therefore, a wide range of field-level applications can be supported by combining valve
devices, sensors, and other devices.
■
Simultaneous Remote I/O and Message Services
Remote I/O communications to constantly exchange I/O data between the PLC and Slaves can be
executed simultaneously with message communications, to send/receive DeviceNet (Master) Unit
data as required by the application. Therefore, a DeviceNet Network can be installed to flexibly han-
dle applications that require both bit data and message data. Message communications can be
achieved either by using OMRON's FINS commands or by using DeviceNet explicit messages.
OMRON Master Unit
OMRON Master Unit
OMRON Configurator
OMRON Configurator
DeviceNet Network
DeviceNet Network
OMRON Slaves
OMRON Slaves
Slaves by other company
Slaves by other company
Slaves by other company
OMRON Slaves
Master by other
company