Chapter 10
10-101
Appendices
L2-04
0485
01
9F
Voltage restart time
0.0 to 5.0 0.1 s
0.3
No
L2-05
0486
01
A0
Under voltage detection level (UV)
150 to
210 (150
to 420)
(See
note 1.)
1 V
190
(380)
(See
note 1.)
No
L2-06
0487
01
A1
Not used.
---
---
0.0
---
L3-01
0488
01
A2
Stall prevention during acceleration
0 to 2
1
1
No
L3-02
0489
01
A3
Stall prevention level during accelera-
tion
0 to 200
1%
150
No
L3-03
048A
01
A4
Stall prevention limit during accelera-
tion
0 to 100
1%
50
No
L3-04
048B
01
A5
Stall prevention during deceleration
0 to 3
1
1
No
L3-05
048C
01
A6
Stall prevention during run
0 to 2
1
1
No
L3-06
048D
01
A7
Stall prevention level during run
30 to 200 1%
160
No
L4-01
0490
01
A8
Frequency detection level
0.0 to
400.0
0.1 Hz
0.0
No
L4-02
0491
01
A9
Frequency detection width
0.0 to
20.0
0.1 Hz
2.0
No
L4-03
0492
01
AA
Frequency detection level (+/
−
)
−
400.0 to
400.0
0.1 Hz
0.0
No
L4-04
0493
01
AB
Frequency detection width (+/
−
)
0.0 to
20.0
0.1 Hz
2.0
No
L4-05
0494
01
AC
Operation when frequency reference is
lost
0, 1
1
0
No
L5-01
0495
01
AD
Number of auto restart attempts
0 to 10
1
0
No
L5-02
0496
01
AE
Auto restart operation selection
0, 1
1
0
No
L6-01
0498
01
AF
Torque detection selection 1
0 to 4
1
0
No
L6-02
0499
01
B0
Torque detection level 1
0 to 300
1%
150
No
L6-03
049A
01
B1
Torque detection time 1
0.0 to
10.0
0.1 s
0.1
No
L6-04
049B
01
B2
Torque detection selection 2
0 to 4
1
0
No
L6-05
049C
01
B3
Torque detection level 2
0 to 300
1%
150
No
L6-06
049D
01
B4
Torque detection time 2
0.0 to
10.0
0.1 s
0.1
No
L7-01
049E
01
B5
Forward torque limit
0 to 300
1%
200
No
L7-02
049F
01
B6
Reverse torque limit
No
L7-03
04A0
01
B7
Forward regenerative torque limit
No
L7-04
04A1
01
B8
Reverse regenerative torque limit
No
L8-01
04A4
01
B9
DB resistor protection
0, 1
1
0
No
L8-02
04A5
01
BA
Inverter overheat detection pre-alarm
level
50 to 130 1
°
C
95
No
L8-03
04A6
01
BB
Operation after Inverter overheat pre-
alarm
0 to 3
1
3
No
Con-
stant
Regis-
ter num-
ber
(hex)
Class 64 (hex)
Name
Setting
range
Setting
unit
Default
setting
Write
during
opera-
tion
In-
stance
At-
tribute
Summary of Contents for 3G3MV-PDRT2
Page 4: ......
Page 12: ......
Page 36: ...Chapter 1 1 22 Functions and System Configuration...
Page 52: ...Chapter 2 2 16 Example System Startup...
Page 94: ...Chapter 4 4 14 SYSDRIVE Inverter Settings...
Page 130: ...Chapter 5 5 36 Remote I O Functions...
Page 234: ...Chapter 8 8 14 Communications Errors...
Page 362: ...R 2 Revision History...