Chapter 6
6-16
Message Communications
01
16
Speed scale
Speed data unit selection
can be set and read. The
speed data unit value is
calculated as follows:
Unit = 1 [r/min] x 1/2
a
a: Speed scale set value
Set a negative value as its
2's complement.
−
15 to 15 (F1
to 0F hex)
00
Yes
Yes
Byte
17
Current scale
Current data unit selection
can be set and read. The
current data unit value is
calculated as follows:
Unit = 0.1 [A] x 1/2
b
b: Current scale set
value
Set a negative value as its
2's complement.
−
15 to 15 (F1
to 0F hex)
00
Yes
Yes
Byte
1A
Power scale
Power data unit selection
can be set and read. The
power data unit value is
calculated as follows:
Unit = 1 [W] x 1/2
c
c: Power scale set value
Set a negative value as its
2's complement.
−
15 to 15 (F1
to 0F hex)
00
Yes
Yes
Byte
1B
Voltage scale
Voltage data unit selection
can be set and read. The
voltage data unit value is
calculated as follows:
Unit = 1 [V] x 1/2
d
d: Voltage scale set
value
Set a negative value as its
2's complement.
−
15 to 15 (F1
to 0F hex)
00
Yes
Yes
Byte
1C
Time scale
Time data unit selection
can be set and read. The
time data unit value is cal-
culated as follows:
Unit = 1 [ms] x 1/2
e
e: Voltage scale set
value
Set a negative value as its
2's complement.
−
15 to 15 (F1
to 0F hex)
00
Yes
Yes
Byte
1D
Reference From
Net
(See note 1.)
00: Reference other than
DeviceNet (n004/b1-01)
01: Operating with
DeviceNet.
---
00
Yes
No
Byte
64
Electric power
Average power value (W)
---
0000
0000
Yes
No
Long
65
Electric power
time scale
Power value measure-
ment period (T) (reflected
when power is turned ON)
00: 10 minutes
01: 30 minutes
02: 60 minutes
00 to 02
00
Yes
Yes
Byte
6F
Specific alarm
Alarm code of the alarm or
minor fault detected in the
Inverter. For more details,
refer to
8-5 Inverter
Alarms
.
---
0000
Yes
No
Word
70
Specific error
Fault code of the fault
detected in the Inverter.
For more details, refer to
8-4 Inverter Faults
.
---
00
Yes
No
Byte
Instance
Attribute
Name
Content
Setting range
Default
Read
Write
Size
Summary of Contents for 3G3MV-PDRT2
Page 4: ......
Page 12: ......
Page 36: ...Chapter 1 1 22 Functions and System Configuration...
Page 52: ...Chapter 2 2 16 Example System Startup...
Page 94: ...Chapter 4 4 14 SYSDRIVE Inverter Settings...
Page 130: ...Chapter 5 5 36 Remote I O Functions...
Page 234: ...Chapter 8 8 14 Communications Errors...
Page 362: ...R 2 Revision History...