Chapter 10
10-86
Appendices
●
Operator Status: Register Number 0011 Hex
●
Fault 1: Register Number 0014 Hex
Note 1.
Maximum (upper limit) temperature was exceeded.
Note 2.
Set temperature was exceeded.
●
Fault 2: Register Number 0015 Hex
Bit
Content
0
1: Operation fault
1
1: EEPROM error
2
1: Program mode
3
00: Operator connecting
11: Operator disconnecting
4
5 to 15
Not used.
Bit
Display
Content
0
PUF
Fuse open
1
UV1
Undervoltage (main)
2
UV2
Undervoltage (CTL)
3
UV3
Undervoltage (MC)
4
SC
Short-circuit
5
GF
Ground fault
6
OC
Overcurrent
7
OV
Overvoltage
8
OH
Overheat (See note 1.)
9
OH1
Overheat (See note 2.)
10
OL1
Motor overload
11
OL2
Inverter overload
12
OL3
Overtorque detection 1
13
OL4
Overtorque detection 2
14
RR
Braking transistor
15
RH
Braking resistor
Bit
Display
Content
0
EF3
External fault (terminal 3)
1
EF4
External fault (terminal 4)
2
EF5
External fault (terminal 5)
3
EF6
External fault (terminal 6)
4
EF7
External fault (terminal 7)
5
EF8
External fault (terminal 8)
6
---
Not used.
7
OS
Overspeed
8 DEV
Speed
deviation
9
PGO
PG is disconnected
10
PF
Input phase loss
11
LF
Output phase loss
Summary of Contents for 3G3MV-PDRT2
Page 4: ......
Page 12: ......
Page 36: ...Chapter 1 1 22 Functions and System Configuration...
Page 52: ...Chapter 2 2 16 Example System Startup...
Page 94: ...Chapter 4 4 14 SYSDRIVE Inverter Settings...
Page 130: ...Chapter 5 5 36 Remote I O Functions...
Page 234: ...Chapter 8 8 14 Communications Errors...
Page 362: ...R 2 Revision History...