External Terminal Function Parameters
F6-01
0395
---
---
Not used.
---
---
0
---
F7-01
0396
---
---
Output pulse multiple selection
0 to 4
1
1
No
F8-01
0398
---
---
Operation selection (E-15)
0 to 3
1
1
No
F9-01
0399
---
---
Communications external fault input
selection
0, 1
1
0
No
F9-02
039A
---
---
Communications external fault input
detection selection
0, 1
1
0
No
F9-03
039B
---
---
Communications external fault input
operation selection
0 to 3
1
1
No
F9-04
039C
---
---
Not used.
---
---
0
---
F9-05
039E
---
---
Torque reference/Torque limit selection
from communications
0, 1
1
1
No
F9-06
039F
---
---
DeviceNet operation selection
0 to 3
1
1
No
Con-
stant
Regis-
ter num-
ber
(hex)
Class 64 (hex)
Name
Setting
range
Setting
unit
Default
setting
Write
during
opera-
tion
In-
stance
At-
tribute
H1-01
0400
01
7E
Multi-function input 1: terminal 3 selec-
tion
0 to 77
1
24
No
H1-02
0401
01
7F
Multi-function input 2: terminal 4 selec-
tion
14
No
H1-03
0402
01
80
Multi-function input 3: terminal 5 selec-
tion
3 (0)
(See
note 1.)
No
H1-04
0403
01
81
Multi-function input 4: terminal 6 selec-
tion
4 (3)
(See
note 1.)
No
H1-05
0404
01
82
Multi-function input 5: terminal 7 selec-
tion
6 (4)
(See
note 1.)
No
H1-06
0405
01
83
Multi-function input 6: terminal 8 selec-
tion
8 (6)
(See
note 1.)
No
H2-01
0406
01
84
Multi-function contact output: terminal
9 to 10.
0 to 37
1
0
No
H2-02
0407
01
85
Multi-function output 1: terminal 25.
1
No
H2-03
0408
01
86
Multi-function output 2: terminal 26.
2
No
H3-01
0409
01
87
Signal selection: terminal 13 (Voltage)
0, 1
1
0
No
H3-02
040A
01
88
Frequency reference (voltage)
gain: terminal 13
0.0 to
1000.0
0.1%
100.0
Yes
H3-03
040B
01
89
Frequency reference (voltage)
bias: terminal 13
−
100.0 to
100.0
0.1%
0.0
Yes
H3-04
040C
01
8A
Multi-function analog input signal
selection: terminal 16
0, 1
1
0
No
H3-05
040D
01
8B
Multi-function analog input signal
selection: terminal 16
0 to 1F
1
1F
No
Con-
stant
Regis-
ter num-
ber
(hex)
Class 64 (hex)
Name
Setting
range
Setting
unit
Default
setting
Write
during
opera-
tion
In-
stance
At-
tribute
Summary of Contents for 3G3MV-PDRT2
Page 4: ......
Page 12: ......
Page 36: ...Chapter 1 1 22 Functions and System Configuration...
Page 52: ...Chapter 2 2 16 Example System Startup...
Page 94: ...Chapter 4 4 14 SYSDRIVE Inverter Settings...
Page 130: ...Chapter 5 5 36 Remote I O Functions...
Page 234: ...Chapter 8 8 14 Communications Errors...
Page 362: ...R 2 Revision History...