Chapter 5
5-28
Remote I/O Functions
●
Input Bit Details (Inputs 0 to 7)
Note 1.
A shaded box indicates that the bit is not used.
Note 2.
The bits in the multi-function input monitor will be turned ON not only when the terminal’s
signal is ON, but also when the corresponding bit is turned ON from remote I/O. (The termi-
nal’s ON/OFF status is logically ORed with the status of the bit sent through remote I/O.)
Note 3.
Setting n50 to n56 to 27 to 33 enables using the terminals for sending notification to the PLC.
Name
Function
3G3MV
3G3RV/3G3PV
3G3FV
Input 0
Status of terminal S1
(multi-function input 1)
(See note 3.)
Status of terminal S1
(Forward/Stop)
Status of terminal 1
(Forward/Stop)
Input 1
Status of terminal S2
(multi-function input 2)
(See note 3.)
Status of terminal S2
(Reverse/Stop)
Status of terminal 2
(Reverse/Stop)
Input 2
Status of terminal S3
(multi-function input 3)
Status of terminal S3
(multi-function input 1 selection)
Status of terminal 3
(multi-function contact input 1)
Input 3
Status of terminal S4
(multi-function input 4)
Status of terminal S4
(multi-function input 2 selection)
Status of terminal 4
(multi-function contact input 2)
Input 4
Status of terminal S5
(multi-function input 5)
Status of terminal S5
(multi-function input 3 selection)
Status of terminal 5
(multi-function contact input 3)
Input 5
Status of terminal S6
(multi-function input 6)
Status of terminal S6
(multi-function input 4 selection)
Status of terminal 6
(multi-function contact input 4)
Input 6
Status of terminal S7
(multi-function input 7)
Status of terminal S7
(multi-function input 5 selection)
Status of terminal 7
(multi-function contact input 5)
Input 7
Status of terminal 8
(multi-function contact input 6)
OR
OR
S3
S4
S5
S6
S7
OR
OR
OR
S1
S2
OR
OR
S3 (3)
S4 (4)
S5 (5)
S6 (6)
S7 (7)
OR
OR
OR
S1 (1)
S2 (2)
S8 (8)*
OR
3G3MV Inverter
DeviceNet Unit
DeviceNet
Communications Card
3G3RV/3G3FV Inverter
Inverter control
Inverter control
MFI 1 (n50)
MFI 2 (n51)
MFI 3 (n52)
MFI 4 (n53)
MFI 5 (n54)
MFI 6 (n55)
MFI 7 (n56)
Input 0
Input 1
Input 2
Input 3
Input 4
Input 5
Input 6
Input 0
Input 1
Input 2
Input 3
Input 4
Input 5
Input 6
Input 7
Bit 2 (MFI 1 selection)
Bit 3 (MFI 2 selection)
Bit 4 (MFI 3 selection)
Bit 5 (MFI 4 selection)
Bit 6 (MFI 5 selection)
Bit 7 (MFI 6 selection)
Bit 2 (MFI 3 selection)
Bit 3 (MFI 4 selection)
Bit 4 (MFI 5 selection)
Bit 5 (MFI 6 selection)
Bit 6 (MFI 7 selection)
TBI 1 (forward/stop)
TBI 2 (reverse/stop)
MFI 3 (H1-01)
MFI 4 (H1-02)
MFI 5 (H1-03)
MFI 6 (H1-04)
MFI 7 (H1-05)
MFI 8 (H1-06)
(See note 2.)
Note 2: 3G3FV only
Terminal
Block
inputs
Control I/O remote I/O
word n
Control I/O remote I/O
word n
Terminal
Block
inputs
Word m+4
Word m+4
Note 1: MFI = Multifunction input, TBI = Terminal Block input
Summary of Contents for 3G3MV-PDRT2
Page 4: ......
Page 12: ......
Page 36: ...Chapter 1 1 22 Functions and System Configuration...
Page 52: ...Chapter 2 2 16 Example System Startup...
Page 94: ...Chapter 4 4 14 SYSDRIVE Inverter Settings...
Page 130: ...Chapter 5 5 36 Remote I O Functions...
Page 234: ...Chapter 8 8 14 Communications Errors...
Page 362: ...R 2 Revision History...