Chapter 7
7-60
Configurator Settings
7-4-5 Warning Torque Tab Page
Item
Details
Reference
Accel/Decel
Torque Current
Displays the current level during acceleration/deceleration.
Note: The present value or most recent value is displayed.
7-2-3 Warning Torque
Detection
Accel/Decel Peak
Torque
Displays the maximum current level during acceleration/
deceleration.
Note: The setting can be cleared to zero by clicking the
Clear Button to the right of the setting.
Warning Torque
during Accel/Decel
Displays this item as selected when the current level
exceeds the monitor value (threshold) during acceleration/
deceleration.
Torque Current
during Frequency
Agree
Displays the current level during frequency agreement.
Note: The present value or most recent value is displayed.
Peak Torque dur-
ing Frequency
Agree
Displays the maximum current level during frequency agree-
ment.
Note: The setting can be cleared to zero by clicking the
Clear Button to the right of the setting.
Warning Torque
during Frequency
Agree
Displays this item as selected when the current level
exceeds the monitor value (threshold) during frequency
agreement.
Clear Error Flag
Button
Clears the Warning Torque Detection Flag in the Unit’s Sta-
tus Area.
Note 1: This button is enabled when the
Status Hold
field
is
selected on the Warning Torque Tab Page of the Edit Device
Parameters Window.
Summary of Contents for 3G3MV-PDRT2
Page 4: ......
Page 12: ......
Page 36: ...Chapter 1 1 22 Functions and System Configuration...
Page 52: ...Chapter 2 2 16 Example System Startup...
Page 94: ...Chapter 4 4 14 SYSDRIVE Inverter Settings...
Page 130: ...Chapter 5 5 36 Remote I O Functions...
Page 234: ...Chapter 8 8 14 Communications Errors...
Page 362: ...R 2 Revision History...