CHAPTER 15 FLASH MEMORY (
µ
PD70F3114)
610
User’s Manual U15195EJ5V0UD
15.5.3 RESET pin
When connecting the reset signals of the dedicated flash programmer to the RESET pin, which is connected, to the
reset signal generator on-board, a conflict of signals occurs. To avoid the conflict of signals, isolate the connection to
the reset signal generator.
When the reset signal is input from the user system in flash memory programming mode, the programming
operation will not be performed correctly. Therefore, do not input signals other than the reset signals from the
dedicated flash programmer.
Figure 15-8. Conflict of Signals (RESET Pin)
V850E/IA2
RESET
Output pin
Reset signal generator
Dedicated flash programmer connection pin
Conflict of signals
In the flash memory programming mode, the signal
the reset signal generator outputs conflicts with the
signal the dedicated flash programmer outputs.
Therefore, isolate the signals on the reset signal
generator side.
15.5.4 NMI pin
Do not change the input signal to the NMI pin in flash memory programming mode. If it is changed in flash memory
programming mode, programming may not be performed correctly.
15.5.5 MODE0, MODE1 pins
To shift to the flash memory programming mode, set MODE0 to high level, apply the writing voltage (7.8 V) to the
MODE1/V
PP
pin, and release reset.
15.5.6 Port pins
When the flash memory programming mode is set, all the port pins except the pins which communicate with the
dedicated flash programmer become output high-impedance status. Nothing need be done to these port pins. If
problems such as disabling output high-impedance status should occur to the external devices connected to the ports,
connect them to V
DD
or V
SS
via resistors.
15.5.7 Other signal pins
Connect X1 and X2 to the same status as in the normal operation mode.
The amplitude is 3.3 V.
15.5.8 Power supply
Supply the power supply (V
DD
, V
SS
, V
SS3
, AV
DD0
, AV
DD1
, AV
SS0
, AV
SS1
, CV
SS
, RV
DD
) the same as in normal
operation mode. Supply 3.3 V to the REGIN pin from the dual-power-supply adapter (FA-TVC).