CHAPTER 9 TIMER/COUNTER FUNCTION
399
User’s Manual U15195EJ5V0UD
Figure 9-103. Example of Timing During TM4 Operation
(a)
When TM4
<
CM4
TM4
TM4CAE0
TM4CE0
CM4
INTCM4
M
N
N
N
Remark
M = TM4 value when overwritten
N = CM4 value after overwrite
M < N
(b) When TM4
>
CM4
TM4
TM4CAE0
TM4CE0
CM4
INTCM4
M
FFFFH
N
N
N
Remark
M = TM4 value when overwritten
N = CM4 value after overwrite
M > N