CHAPTER 9 TIMER/COUNTER FUNCTION
383
User’s Manual U15195EJ5V0UD
Figure 9-92. TM3 Capture Operation Example (When Both Edges Are Specified)
TM3
∆
Count start
TM3CE
←
1
∆
Overflow
TM3OVF
←
1
D0
D1
D2
D0
D1
D2
Interrupt request (INTP31)
(TM3 count values)
Capture register (CC31)
Remark
D0 to D2: TM3 count values