11.6.45.14 Error 49-13 (emergency code 6100h)
Cause: Error on safety drive SR1 detected
Suggested steps:
Read additional information, check safety system or wiring and acknowledge
alarm/error
Extended diagnosis of safety
errors/alarms.
l
Further information on the error/alarm code
can be found in the "MSD Servo Drive
Software with Safety PLC Function".
An error occured at the
safety controller.
l
Please check the safety program and the
wiring of the security system.
l
Please acknowledge the error on the affected
device. Subsequently the alarm must be
acknowledged at the safety master to reset the
network status to "RUN".
l
Please restart the application (24V reset).
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
434
11 Alarms & warnings
11.6.45.15 Error 49-14 (emergency code 6100h)
Cause: Error on safety drive SR2 detected
Suggested steps:
Read additional information, check safety system or wiring and acknowledge
alarm/error
Extended diagnosis of safety
errors/alarms.
l
Further information on the error/alarm code
can be found in the "MSD Servo Drive
Software with Safety PLC Function".
An error occured at the
safety controller.
l
Please check the safety program and the
wiring of the security system.
l
Please acknowledge the error on the affected
device. Subsequently the alarm must be
acknowledged at the safety master to reset the
network status to "RUN".
l
Please restart the application (24V reset).