11.6.7.4 Error 6-4 (emergency code 4310h)
Cause: PTC/TSS error, resistance still higher than 1650 Ohm after overtemperature
Suggested steps:
Wait and let motor cool down. Reduce motor load or change motion cycle.
The motor temperature is too
high.
l
Please let the motor cool down
l
Please check motor temperature and motor
temperature resistance (PTC sensors do not
report the motor temperature). If the values are
not plausible, check cables and sensor type.
l
If you are not using a system motor, please
check with the motor manufacturer if the motor
can stand a higher temperature
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
340
11 Alarms & warnings
11.6.7.5 Error 6-5 (emergency code 4310h)
Cause: Motor protection method not supported
Suggested steps:
Try to use different sensor connection, or contact your service provider
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.